| Time |
The
luminance of the sample (mcd/m2) |
| (
min ) |
SYSTEM
- SL/2
f & p |
SYSTEM
- SL/5 f
& p |
SYSTEM
ALU-SL/5 |
ALU-SL/8* |
PC
- POLYCARBONATE |
| 2 |
513,71
|
682,7 |
951,2
|
1486,2 |
650,7 |
| 10 |
106,31 |
140,9 |
195,2 |
319,2 |
234,9 |
| 30 |
33,51 |
43,7 |
58,2 |
96,2 |
41,6 |
| 60 |
15,31 |
19,7 |
26,0
|
42,0 |
18,7 |
| 120 |
6,73 |
8,6 |
11,0
|
17,5 |
8,0 |
|
The time after which the sample is gaining
border value of 0,32 mcd/m2 |
| |
1710
min |
2010
min |
2740
min |
3200
min |
1880
min |
| The
percent above the DIN 67510 standard which is 340 min |
| |
502,9
% |
591,2% |
805,9% |
941,2% |
552,9% |
| Remember
- the more glowing the more safety !!! |
| |
(
min ) |
SYSTEM
TD-SL/2 |
SYSTEM
TD-SL/5 |
2 |
342,8 |
478,7 |
10 |
76,3 |
97,5 |
30 |
23,8 |
29,9 |
60 |
10,7 |
13,3 |
120 |
4,7 |
5,7 |
| |
The
time after which the sample is gaining border value of 0,32
mcd/m2 |
| |
1270
min |
1420
min |
All
Certificates and researches
|
CH
1
Arterglow times of SL SYSTEMS in comparison with the DIN 67510 norm

CH
2
f & p SL/2
SYSTEM timesteps with glowing values after 2,10,30,60,120 min in comparison
withe the DIN 67510 standard.

CH
3
f & p SL/5
SYSTEM timesteps with glowing values after 2,10,30,60,120 min in comparison
withe the DIN 67510 standard.
WHY
HAVING GOOD TIMESTEPS WITH GLOWING VALUES IS IMPORTNANT IN EMERGENCY |
It
is importnant to show good glowsteps values because: Regarding
the statiscts data that show that during average fire intensity
that takes place in a building, the rescue ac tions and emergency
should be led in a time of 40 minutes. Because after that mostly
there are tiny chances to save ones lives. So the statistic
intensity of fire the emergency escape action should take about
30 minutes. That is why we show the steps data which are really
good. Because during exactly that time the emergency action
should be taken and the glowing intensity of the safety signs
is MOST IMPORTANT. Showint the afterglow time as many companies
is god, but sometimes it is absolutely unnecessary to manuracture
signs glowing for 5000 min as some companies does. We put most
of the stress on that how the glowing behaves after 10, 30 and
the 60 minutes. Of coure Afterglow time is importnant, becuse
it is connected with the good timesteps in glowing values, but
not always (please see our charts - exponential shape of function)
.Try to imagine what would happen in a builbing that average
fire took place after for example 5000 minutes that give 83
hours and that gives 3,5 days in a fire. After that time there
will be no rescue action after more than 3 days. So we do not
pay that much attention to the afterglow time as to timesteps
in glowing values issues. We do not try to follow the international
trend in showing the extreme afterglow times as a marketing
action. We rather try to cunstruct the sign which will appear
bestly in the most importnant time for human's life. |
| weight: |
0,49
g /cm3 |
| thickness: |
about
1,9 mm |
|
Luminiscence: |
Measured
in relation to the DIN 67510 standard |
|
Toxicity: |
Non
Toxic. The certificate of The National Institute of Hygiene in
Warsaw HK / B /1045 / 01 / 2002 |
|
Radioactivity
: |
Non
Radioactive - The Report of the Central Laboratory of Radiological
Protection in Warsaw Nr Z-II / 52 / 04.2002 |
| The range
of usage temperatures: |
- 40°
C to + 90° C |
|
Resistance
to getting old: |
While
the 3 years research in rooms withe temperature above 0° C
- no changes have been noticed. |
|
Type of
the glue: |
Acril
glue on a basis of polyurethane. |
| Resistance
to cutting off from the steel: |
In
Relation to DIN EN 1943 in temperature + 23°C +/- 20°C
= 40N/625 mm2 |
| Resistance
from tearing away from the steel: |
In
Relation to DIN EN 1943 in temperature + 23°C +/- 20°C
= 28N/25 mm (stratification of the polyurethane foam) |
| Maximal
final attachemant:
|
After
24 hours. |
| The Temperature
of stocking: |
Room
Temperature and usual humidity 50 - 70% |
|
Certificates:
|
1.
National Institute of Hygiene in Warsaw
2. Central Laboratory of Radiological Protection in Warsaw
3. The Radiotecnical Institute in Gdansk
4. Polish Ship Registry PRS in Gdansk
5. CNBOP Jozefow
6. The Research Laboratory Of The Branch Office of Electrotecnical
Institute in Gdansk |
Resistance to
the cyclical serial heat:
|
Humidity
98% and the temp. 25° C and 60° C
The Research Laboratory Of The Branch Office of Electrotecnical
Institute in Gdansk - No changes have been noticed. |
| Resistance
to the low temperature: |
-30°C
The Research Laboratory Of The Branch Office of Electrotecnical
Institute in Gdansk - No changes have been noticed. |
|
Technical
Parameters Of The luminescent Floor Systems |

|
Название
изделия: |
Эвакуационные
знаки и напольная разметка
Толщина: около 0,13 мм |
| Thickness: |
About
0,13 mm |
|
Яркость: |
Для SL/2 62,8/4,9 - 515 / DIN 67510
Для SL/5 115,0/9,0 - 815 / DIN 67510
Измерение яркости свечения проведено согласно стандурту DIN |
| Destination:
|
Floor
routes and signs and for emergency routes in rooms liks production
halls, magazines, passages etc. |
| Way
of montage: |
Sticking
with self advesive included in the product after preparing the
basis. |
| Ranges
of usage temperatures: |
- 40°
C to + 90° C |
| Montage
conditions: |
The
basis must be dry, smooth, free of dust and pollution and cleaned
with alcohol. |
| Montage
issues: |
- Resistance
to getting worn.
- Resistance to chemical cleaning products
- Resistance to huge mechanical loads (possiility of drive through
by heavy equipment like fork lift trucks etc.) |
| Operation
issues : |
Signs
and routes once stack, can not be used once again. |
| Every
kind of sign can be luminescent of non luminescent depanding
on the demand |
| We
offer our signs in materials
given below:
|
1)
pn - non luminescent board
2) ps - luminescent board
3) fn - non luminescent foil
4) fs - luminescent foil
5) ts - luminescent TD SYSTEM® board
6) Alu - Aluminum |
| Every
sign can be made in different kind of technology:
|
1)
SL/2
2) SL/5
3) SL/8 |
Examples of usage of safety luminescent systems by TOP-DESIGN
CHWASZCZYNO S.J
 |
*
The company has ready prototypes of products SL/8, that can be brought
into stable production. All questions regarding this subject please
refer to our office at office@signs-tdc.com |
|